Перевод: с русского на все языки

со всех языков на русский

customer interface module

  • 1 блок интерфейса заказчика

    Универсальный русско-английский словарь > блок интерфейса заказчика

  • 2 блок управления с интерфейсом заказчика

    Универсальный русско-английский словарь > блок управления с интерфейсом заказчика

  • 3 параллельная система ИБП

    1. parallel UPS system

     

    параллельная система ИБП
    -

    [Интент]

    Parallel Operation: The system shall have the option to install up to four (4) UPSs in parallel configuration for redundancy or capacity.
    1. The parallel UPS system shall be of the same design, voltage, and frequency. UPS modules of different size ratings shall be permitted to be paralleled together for purposes of increased capacity or UPS module redundancy. The UPSs in the parallel configuration shall not be required to have the same load capacity rating.
    2. Parallel Capacity: With N+0 system-level redundancy, up to 2MW of load can be supported by the system.
    3. Parallel Redundancy: With N+1 system-level redundancy, up to 1.5MW of load can be supported by the system, and only the UPS being replaced must be isolated from the source (bypass operation is not required for the entire system during the UPS replacement procedure).
    4. Output control: A load sharing circuit shall be incorporated into the parallel control circuits to ensure that under no-load conditions, no circulating current exists between modules. This feature also allows each UPS to share equal amounts of the total critical load bus. The output voltage, output frequency, output phase angle, and output impedance of each module shall operate in uniformity to ensure correct load sharing. This control function shall not require any additional footprint and shall be an integral function of each UPS. The static bypass switches shall be connected in parallel.
    5. Parallel System Controls: To avoid single points of failure, the UPS system shall have no single dedicated control system designed to control the operation of the parallel UPS system. Control of and direction of parallel UPSs shall take place via a master/slave relationship, where the first UPS to receive logic power asserts itself as a master. In the event of a master failure, a slave UPS shall take the role of master and assume the responsibility of the previous master UPS. Regardless of which UPS is master or slave, user changes to the system status, such as request for bypass, can be done from any UPS connected to the bus and all UPS on the bus shall transfer in simultaneously.
    6. Communication: Communication between modules shall be connected so that the removal of any single cable shall not jeopardize the integrity of the parallel communication system. Load sharing communications shall be galvanically isolated for purposes of fault tolerance between UPS modules. A UPS module's influence over load sharing shall be inhibited in any mode where the UPS inverter is not supporting its output bus. Transfers to and from bypass can be initiated from any online UPS in the system.
    7. Display: Each UPS multi-color LCD touch screen user interface shall be capable of using an active touch screen mimic bus to show the quantity of UPS(s) connected to the critical bus, as well as the general status of each UPS, such as circuit breaker status information. Any touchscreen display shall support the configuration of the [entire parallel] system and shall provide event and alarm data for all UPSs in the parallel configuration. A Virtual Display Application shall be available for download to the customer’s computer and shalll support remote monitoring of a complete system with up to 4 UPSs in parallel.
    8. Battery runtime: Each UPS must have its own battery solution. The battery solution for the entire system can be a combination of standard and third-party batteries, but each UPS must use only one battery solution – either standard or third-party batteries.
    9. Switchgear: A custom switchgear option shall be required for parallel operation.

    [Schneider Electric]

    Тематики

    EN

    Русско-английский словарь нормативно-технической терминологии > параллельная система ИБП

См. также в других словарях:

  • Subscriber Identity Module — Simcard redirects here. For the brand name medication, see Simvastatin. A typical SIM Card …   Wikipedia

  • Elastic interface bus — Overview= Elastic Interface buses (EI bus connections) can be generalized as bus connections which are high speed interfaces that have clock sent with data. All of the data bits are aligned to the clock to be able to latch the data at these high… …   Wikipedia

  • Fiber to the x — (FTTX) is a generic term for any network architecture that uses optical fiber to replace all or part of the usual copper local loop used for telecommunications. The four technologies, in order of an increasingly longer fiber loop are:* Fiber to… …   Wikipedia

  • Holistic Data Management — (HDM) framework is AHISDATA indigenous standard for implementing software implementations within an organization network. This framework extends the existing data management solutions such as data quality, data governance, data integration, data… …   Wikipedia

  • Truck scale software — is a class of software pertaining to the collection of transactional scale weighment data. Specifically for truck scales used to weigh heavy trucks, light trucks, or other commercial vehicles. The basic concept of Truck Scale Software is to… …   Wikipedia

  • Abkürzungen/Computer — Dies ist eine Liste technischer Abkürzungen, die im IT Bereich verwendet werden. A [nach oben] AA Antialiasing AAA authentication, authorization and accounting, siehe Triple A System AAC Advanced Audio Coding AACS …   Deutsch Wikipedia

  • Liste der Abkürzungen (Computer) — Dies ist eine Liste technischer Abkürzungen, die im IT Bereich verwendet werden. A [nach oben] AA Antialiasing AAA authentication, authorization and accounting, siehe Triple A System AAC Advanced Audio Coding AACS …   Deutsch Wikipedia

  • Enterprise JavaBean — Simple EJB2 Architecture Enterprise JavaBeans (EJB) is a managed, server side component architecture for modular construction of enterprise applications. The EJB specification is one of several Java APIs in the Java EE specification. EJB is a… …   Wikipedia

  • Microsoft Dynamics GP — is a mid market business accounting software or ERP Software package marketed in North and South America, UK and Ireland, the Middle East, Singapore, Australia and New Zealand. It is used in many additional countries with partner supported… …   Wikipedia

  • CATER Project — CATER is a 3 year collaborative research project launched in September 2006 and supported by the European Commission under the Sixth Framework Programme (DG Information Society and Media). In this context, CATER is a Specific Targeted Research… …   Wikipedia

  • Liste von Abkürzungen (Computer) — Dies ist eine Liste technischer Abkürzungen, die im IT Bereich verwendet werden. Inhaltsverzeichnis A B C D E F G H I J K L M N O P Q R S T U V W X Y Z siehe auch: Liste von Dateiendu …   Deutsch Wikipedia

Поделиться ссылкой на выделенное

Прямая ссылка:
Нажмите правой клавишей мыши и выберите «Копировать ссылку»